This is an alert about new products, services, trainings, jobs, weather, sales, holidays, closings, etc.
AFUE Rating | : | 97 % |
Amperage Rating | : | 14.8 A Maximum, 19.1 A Unit |
Blower Size | : | 11 in Dia x 10 in W |
CFM Rating | : | 2200 cfm |
Cabinet Dimensions | : | 21 in W x 29-1/2 in D x 35 in H |
Configuration | : | Multi-Position |
Connection Type | : | 1/2 in NPT |
Frequency Rating | : | 60 Hz |
Fuel Type | : | Natural Gas |
HP Rating | : | 1 hp at 300 to 1300 rpm |
Input BTU Rating | : | 100000 Btu/hr |
Material | : | Steel |
Number of Burners | : | 5 |
Phase | : | 1 ph |
Series | : | G9MAE |
Temperature Rise | : | 50 - 80 deg F Initial, 35 - 65 deg F Low, 45 - 75 deg F High |
Tonnage | : | 5.5 ton at 400 cfm, 6 ton at 350 cfm |
Transformer Rating | : | 40 VA at 24 VAC |
Voltage Rating | : | 115 VAC |
KeepRite® Gas Furnace, Series: G9MAE, 100000 Btu/hr Input BTU Rating, 115 VAC, 14.8 A Maximum, 19.1 A Unit, 2200 cu-ft/min, 1 hp at 300 - 1300 rev/min, 97% AFUE, 1 -Phase, 60 Hz, Configuration: Multi-Position, 1/2 in NPT Connection, Natural Gas Fuel, 5 -Burner, 10 in W x 11 in Dia Blower Size, 21 in W x 35 in H x 29-1/2 in D Cabinet Dimensions, 5.5 ton at 400 cu-ft/min, 6 ton at 350 cu-ft/min, 40 V-A at 24 VAC Transformer, Steel, 50 - 80 deg F Initial, 35 - 65 deg F Low, 45 - 75 deg F High Rise
- Extra SEER variable speed ECM blower motor
- Supports one and two-stage cooling units
- Dehumidification feature in cooling
- 24 VAC humidifier terminal and electronic air cleaner terminal
- Certified to leak 2% or less of nominal air conditioning cu-ft/min delivered when pressurized to 1 in WC with all present air inlets, air outlets and condensate drain ports sealed
- Tougher - flame roll-out sensors standard, adjustable heating blower off delay, factory set blower on delay, RPJ aluminized heat exchanger, stainless steel secondary heat exchanger, high temperature limit control prevents overheating, direct ignition with silicon nitride igniter
- Quieter - operates quieter at lower heating rates, variable speed induced draft combustion blower
- Direct vent (2-pipe) or ventilated combustion air
- Innovative knobs for easy door removal and secure attachment
- Through the casing flue pipe for counterflow or horizontal applications with accessory
- Four position upflow/down flow/horizontal installation
- At least 12 different venting configurations
- Self configuring and communicating control
- Slide out heat exchanger and blower assembly
- Modulating ECM variable speed blower
- Extra AFUE efficiency
- 4.5 - 13.6 in WC inlet gas pressure