Amperage Rating | : | 7 A |
CFM Rating | : | 1850 cfm |
Configuration | : | Downflow/Front Return |
Cooling Capacity | : | 36000 to 60000 Btu |
Dimensions | : | 57 in H x 19-3/4 in W x 23-3/4 in D |
Filter Size | : | 18 x 20 x 1 in |
Finish | : | Painted Galvanized |
Fuse Rating | : | 25/60 A |
HP Rating | : | 1 hp |
Material | : | Steel |
Motor Type | : | Constant Torque ECM |
Pressure Rating | : | 0.1 in-WC |
Series | : | AED Series |
Voltage Rating | : | 240 V |
Aspen Air Handler, Series: AED Series, 36000 to 60000 Btu Cooling Capacity, 240 V, 7 A, 1 hp, 1850 cfm, Downflow/Front Return, 25/60 A Fuse Rating, 18 x 20 x 1 in Filter, Constant Torque ECM Motor, 0.1 in-WC, Steel, Finish: Painted Galvanized, 57 in H x 19-3/4 in W x 23-3/4 in D
- APPLICATION VERSATILITY - Designed for the manufactured home market with flexibility in mind. One-piece air handler with the ability to be factory built as upflow (solid door) or downflow (louvered door) air handler. Can also be field configured to opposite configuration with the proper conversion kit. (Kits sold separately). 2 - 5 tons of cooling or heating airflow with a range of electric heat kits. Coils are not included and sold separately
- MOTOR - Constant torque ECM, speeds and torque controlled by software to maintain constant torque*. Direct drive blowers circulate air quietly and efficiently. Motor speeds and torques pre-programmed in the motor at the factory. Blowers mounted on rails so they can be easily removed for service
- CABINET - Sturdy, galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2" micro mat non-hygroscopic insulation to prevent sweating, to encapsulate glass fibers, and to provide excellent R-value. Mechanical fastening ensure insulation remains in place
- MODULAR ELECTRIC HEAT KITS - Heat kits available with either circuit breakers or terminal blocks. Available from 3 to 20 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Modules are easily installed in the field using molex plugs or can be ordered factory-installed. Controls are accessible from the front for easy service. Disconnect does not protrude through the wall panel
- Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. Automotive pull-style fuse integrated into board for easy diagnosis and replacement of fuse
- Hassle-free five-year limited parts warranty