Additional Information | : | PVC Face |
Amperage Rating | : | 15 A |
Body Material | : | Polycarbonate |
Color | : | White |
Contact Material | : | Brass |
Dielectric Strength | : | 2000 V |
Grounding | : | Grounding |
Height | : | 1.27 in |
Indicator Type | : | Light |
Length | : | 4.2 in |
Mounting Type | : | Flush |
NEMA Rating | : | NEMA 5-15R |
Number of Poles | : | 2 |
Number of Wires | : | 3 |
Phase | : | 1 ph |
Short Circuit Rating | : | 10 kA |
Temperature Rating | : | -35 to 66 deg C |
Terminal Type | : | Back Wired, Side Wired |
Voltage Rating | : | 125 VAC |
Width | : | 1.68 in |
Wire Size | : | 14 to 10 AWG |
Arrow Hart Receptacle, 125 VAC, 15 A, 1 ph Phase, 10 kA Short Circuit, 2 Poles, 3 Wires, 14 to 10 AWG Wire, Grounding Grounding, NEMA Rating: NEMA 5-15R, 2000 V Dielectric Strength, Light Indicator, Flush Mounting, Back Wired, Side Wired Terminal, Polycarbonate Body, Brass Contact, White, -35 to 66 deg C, 4.2 in Length, 1.68 in Width, 1.27 in Height, Additional Information: PVC Face
- Performs periodic self-tests to ensure integrity of GFCI protection
- Visual trip indicator light gives quick notification of a tripped or "end of life" condition
- Meets and exceeds 10 kA short-circuit testing and Underwriters Laboratories (UL) UL943 safety standards
- Automatic grounding system eliminates the need for bonding jumper in grounded metal enclosure and provides redundant measure of ground continuity where a jumper is used
- Ground termination with back-wire clamp provides secure wiring and reduces installation time
- Tamper-resistant shutters help prevent foreign objects from being inserted
- Line side terminals are backed out and staked for fast installation
- Horizontal test/reset button alignment provides larger unobstructed area
- Test and reset buttons are color matched to provide superior aesthetics
- Tapered back-wire openings handle multiple wire sizes and types for applications up to #10 AWG solid or stranded wire
- When downstream receptacles are wired from load side, a 20 A feed through rating offers full protection
- Black tamper-resistant shutters create seamless look
- Line-load miswiring protection GFCIs will not provide power downstream when wired incorrectly
- Tri-combo head terminal and mounting screws
- UL listed, fully compliant with all latest UL943 Class A GFCI requirements
- Tamper-resistant models comply with 2017 and 2020 NEC Article 406.12
- Weather-resistant models comply with 2017 and 2020 NEC Article 406.9 that states that all receptacles installed in wet or damp locations must be weather-resistant
- Longer, wider "bridged" strap provides 40% more contact area with wallboard, virtually eliminating floating installations